OMC-040, OMC-042 version changes V2.9 B3 - INW sensors -> Bug fix - Adding of partial seconds to csv and json data format timestamp when logging frequency is higher than one Hz V2.9 B2 - Showing in runtime mode when deployment starts, if applicable - Adding of partial seconds to native data format timestamp when logging frequency is higher than one Hz - Analog linear conversion function (2 points calibration) -> Measurement point 1 and 2 can now both be reversed (high or low point) - Bug fix sleep mode for OMC-042 only -> Sleep current was too high (3 mA instead of fewer than 100 uA) (in prior FW2.9 B1 version only) V2.9 B1 - TCP driver -> Option added for data encryption (AES-128) - Bug fix NTP driver -> Preventing possible wrong time update when NTP server sends a “Kiss-o'-Death Packet” (very rare occurring) - Iridium satellite driver -> Option added for data compacting V2.8 B1 - Start measurements right after configuration has changed - Bug fix data sending -> Occasionally occurring SD card failures could cause data loss, especially when sending large data files after long time no network coverage - Bug fix data download -> Download of to less data (end record was not reached) - Bug fix data download -> Preventing the apparently for no reason sometimes displayed "file write error" message V2.7 B1 - Alarm messages driver (previously only SMS) adapted to send alarms also via Email - Timeout and retries enlarged when receiving temporarily network access denied - Bug fix Modem maintenance -> Modem firmware upgrade function improved V2.5 B3 - Bug fix sleep mode -> Sleep current was too high (3 mA instead of fewer than 100 uA) (in prior FW2.5 and FW2.4 versions only) V2.5 B2 - FTP driver -> Option added for secure file transfer (TLS(explicit)) - TCP latency timeout enhancement (timeout starts now after last byte is transmitted) - Bug fix Network signal sensor -> retrying when SIM reports busy (CME ERROR: SIM busy) - External power too low detection removed - Generic Modbus/RTU sensor driver extended to 20 parameters - Bug fix HTTP interface -> Communication buffer enlarged to handle huge cookies V2.4 B7 - Bug fix internal sensors driver -> power sensor reflected wrong current and voltage readings (in prior FW2.4 versions only) V2.4 B5 - Gonets Satellite modem driver -> Maximum of power down time increased to 20 minutes - Email driver -> Option added to filter output (data, diagnostics, or both) - Digital alarm driver -> direct data output on alarm rising/falling if "Direct data output on data alarm" is set V2.4 B3 - Bug fix serial ports -> suppressing erroneous NULL character output after waking from sleep V2.4 B2 - Gonets Satellite modem driver added - General settings -> Option added for data log timestamp round down - FTP driver -> Option added to omit timestamp in filename - Bug fix Iridium satellite driver -> Coping with odd behavior of some Iridium modems (missing "READY" after AT+SBDWB=xx command) - Iridium satellite driver modified for data output fall back during Email, FTP, TCP or HTTP failures - Iridium satellite driver modified for sending log data or actual values V2.2 B6 - Planeta Satellite modem driver added - Bug fix internal sensors driver -> current can now be measured when supply voltages is above 3.75 Volt - Bug fix NTP Time update -> Preventing wrong time update when network connection is lost at critical point - Comport redirect function -> Command echo implemented for SDI12 - SDI12 sensor driver -> Allowing multiple concurrent (aC! and aCX!) commands with the same sensor address - Additional JSON data format added for Email, FTP and TCP output - HTTP output driver added - Modem maintenance function added to test hardware lines (DTR/CTS and DCD) - DTU driver -> Connect interval independent from data log interval - Generic serial sensor driver -> Option added for variable waiting time for data - Digest authentication option added for TCP output - Bug fix alarm module -> Some odd behavior on data transmission when alarm is cleared and when using alarm intervals in combination with send delay V2.1 B4 - Starting direct measurement and data log on digital alarm rising/falling - Bug fix SMS sending -> retrying when SIM reports busy (CMS ERROR 314) - Bug fix CSV data output format -> parameters without data logging flag were not skipped - Editing function added for configuration strings (insert mode with arrow left/right and backspace) (OMCTerminal V1.4) - Bug fix SDI12 sensor driver -> Timeout changed for aM! commands, with measurement times larger than 6 sec V2.0 B1 - Improved SD card fault recovery handling - Date format option added for CSV data output - Additional CSV data format added for TCP output - Improved Iridium satellite driver added for data sending - In case of SD card malfunction actual values will be sended at data sending - Support added for 4GB SD cards - Maintence menu -> Bug fix for (re)format SD-Card function - PAP/CHAP authentication option added for APN/VPN login V1.9 B2 - Bug fix NTP Time update -> When logger was in Alarm mode, the NTP Time update keeps on running continously V1.9 B1 - Daily operating time slot added for non 24 hours deployment - Additional CSV data format added for Email and FTP output - Driver added for snapshot cameras model CAM-S0.3M and CAM-D1.3M - Working directory added for FTP output - Analog differential ports -> Bugfix: Parameter value at min and max were not properly stored (only for FW1.8B3, prior versions are OK) - Comport redirect function -> Bugfix to accommodate large SDI-12 commands (upto 60 characters) V1.8 B3 - Network signal sensor -> Parameter "Signal bars (0-5)" added for commonly used signal strength representation - Factor and offset added in parameter settings for conversion of device units to engineering units - Option added for sensor drivers to use the log interval as sampling interval - Various small user interface changes, and displaying actual values at Data log - DTU driver added for a transparent channel between an RS-232, RS-485, or SDI-12 device and host software (TCP-server) - Code added for direct measurement, and data sending when logger is switched on - GPS driver option added for calculation of latitude/longitude alarm limits on deployment - Summer time (daylight saving) option added - Bug fix TCP Data sending -> skipping "CTRL Z" character incase of accidental data mangling on the SD card, which prematurely ends data sending - Digital pulse driver -> Mean Rate parameter calculates now also when quantity parameter is not logged or sample interval is not equal to log interval - Actual Values Overview -> "Timeout" replaced by "No response", if sensor does not work correctly V1.7 B9 - Hybrid feature added to use module power as digital alarm output - NIVUS KDO sensor driver added V1.7 B8 - Generic Serial driver option added for using output start commands V1.7 B7 - Bug fix SDI12 sensor driver > Timeout and retry changed to prevent timeout for sensors with more than approximately 6 to 10 parameters - Bug fix SMS alarm driver -> Now sending HI Alarm SMS intead of Solved SMS, when Alarm drops under HIHI, but still above HI Alarm threshold V1.7 B6 - Bug fix Radio output driver -> Power down and send delay did not work correctly V1.7 B5 - Maintence menu -> Function added to (re)format SD-Card V1.7 B4 - Small bug fixes for TCP terminal use (keeping open TCP link when closing the menu, and closing menu mode when loosing connection) - FTP driver -> Option added for active (default) and passive FTP mode V1.7 B2 - Option added for continuous alarm sampling (Be aware, this is not a very low power option!) - Generic Modbus/RTU sensor driver extended to 16 parameters, and Bit status register type added - Display driver added - Bug fix Digital pulse driver -> Mean rate calculation when there is an alarm log interval, and no sample alarm interval - SDI12 sensor driver extended with the measurement commands aC1! till aC9! and aM! till aM9! V1.6 B9 - EXO sensor driver adapted for both new and old data layout V1.6 B8 - Bug fix Digital pulse driver -> Counter register increased by one at every logger restart, if port mode was internal Pull Up V1.6 B7 - Bug fix Generic Modbus/RTU driver -> Sometimes a driver timeout when reading more than one or two parameters, and option RS485 8N2 added V1.6 B6 - Bug fix Independent data log for GPS and GSM signal driver -> wrong parameters were tagged as logged V1.6 B5 - GPS sensor -> Option added to power the GPS either by the Sensor or by the Module power switch V1.6 B4 - Improved battery life calculation when Modem is on (Idle) during sleep V1.6 B3 - Digital pulse sensors -> Option added to log each counter change event (e.g. for time registration of bucket tipping events in rain gauge applications) V1.6 B2 - Code optimizing with retry mechanism, to cope with accidental faltering SD-Card - Verbose Modem and Network error messages V1.6 B1 - Analog sensors -> User determined linear conversion function (2 calibration points) implemented - Analog differential sensor drivers added for hardware revision 9 V1.5 B9 - 20 seconds and 20 minutes logging and sample interval added - Extended parameter list added for EXO sensor driver V1.5 B8 - STS DTM sensor driver added - SDI12 sensor driver extended to 20 parameters V1.5 B7 - INW DO sensor -> Bug fix - Modem internal baud rate lowered from 115K2 to 57K6, due to incidental character overrun during poor GPRS coverage V1.5 B6 - Analog sensors -> Bug fix: Auto calibration function was wrongly implemented V1.5 B2 - Configuration menu -> Bug fix: Accidental removing of TCP/FTP/Email driver after removing of a Sensor driver (only when the TCP/FTP/Email driver was added after the the Sensor driver) V1.5 - EXO sensor driver added V1.4 B8 - Modem settings -> Deregister network added in provider selection, to solve network access denied situation, due to network blacklist V1.4 B7 - Maintence menu -> Field test Prepaid balance (if applicable) added V1.4 B6 - Automatic NTP time update, incase of lose of time due to static discharge, or backup battery failure, or else - Network registration and APN login timeouts increased from about 30 seconds to 1 minute - Improved retries for zending of longer data files (> 100K of data) V1.4 B4 - Internal sensors -> Power measurement retries increased, to avoid incidental repeating power error and solved SMS - Various user interface bugs fixed (no operational impact) - INW DO sensor driver added V1.4 B3 - Bug fix SD-Card code -> Support added for other Micro SD-Cards V1.4 B2 - Generic MODBUS/RTU driver added V1.4 - Digital pulse sensor -> Mean, Max and Min Rate parameters added - Internal sensors -> Min and Max Voltage parameters added - Maintence menu -> Field test Battery resistance added - SDI12 sensor drivers added for Generic, INW and OTT sensors - ISOMAG ML255 sensor driver added V1.3 B4 - Digital sensors -> Internal Pull Down or Pull up added for digital input - INW PT12 sensor -> Bug fix (skipping first invalid '0' reading) V1.3 B3 - Digital sensor -> Input alarm driver added V1.3 B2 - SMS Commands -> Bug fix: Logger didn't process SMS messages in the 2 Cycle, and didn't go to sleep anymore V1.3 - Interface with OMC-Programmer (V1.6) V1.2 B6 - Modbus sensoren -> Bug fix INW sensoren V1.2 B3 - INW PT12 sensor -> Reported slave ID will now be detected V1.2 - Terminal Link Request in TCP protocol via OMC-Data-Online server - USB port disabling after 5 minutes inactivety on USB port, inorder to preserve power - Operating cycle time takes now configuration and firmware upgrade time into account V1.1 B5 - Digital sensor -> Rate parameter removed V1.1 B4 - Digital sensor -> Quantity parameter is now quantity inbetween data logging intervals instead of inbetween sample intervals - Digital sensor -> Option to preset pulse counter value added - McVan NEP39x sensor -> Bug fix data input reading V1.1 - Maintenace menu -> Down- and Upload of configuration file added - INW CT2X sensor -> Salinity parameter added - Internal sensors -> Battery relaced attribute now defaults to Yes at first instance, or at first config upload V1.0 - First version